| AllFLOW IQ Spirometer | ||
| 5501000 | Clinical Diagnostic Spirometer | 3 8462501000 3 |
| 5502003 | Syringe | |
| 5501333 | Spirometer with Computer | 3 8462501333 2 |

AllFLOW IQ SPECIFICATIONS:
Calibration: 3 litre syringe. Full recall generates a 5th order polynomial fit. ‘Cal Check’ and calibrated dates are displayed on-screen, as well as on the printed report.
Parameters: FVC, FEV1, FEV3, FEV6, FEV1/FVC, FEV1/FEV6, PEFR, FEF25%, FEF50%,FEF75%, FEF25-75,
FEF75- 85, FIVC, PIFR, FIV0.5, FIV1, FIV3, FIV1/FIVC, FIF50%, FET100%, SVC Extrapolated V%, and V(L), Peak rise time.
Tests Performed: FVC, FIVC, PRE/POST Bronchodilator, Flow/Volume Loop, Volume/Time graph, SVC, MVV.
Interpretation: Automatic computer interpretation as per the ‘ATS Interpretive Strategies’ recommendations and provision is made for manual entries as well.
Graphics: Flow/Volume, Volume/Time, Flow/Time as per the ATS/ERS 2005 recommendations for super-imposed graphs, size and scale. Predicted expiratory graph and trends are also displayed.
Reports: Standard as per the ATS 2005 recommendations, which include: pre/post, trending, automatic best test, user selectable best test and bar-graph (for easy analysis). Quality control parameters on how the test was performed, is also displayed on the report (ATS 1994 & ATS/ERS 2005 updated recommendations). In addition, the data can be exported to MS Excel and the reports can be converted to ‘meta files’ to allow the graphical insertion of this into other reports/documents/software. Available with two reports; condensed and full page.
Data Sample Rate: 335 samples / second (high sample rate for high resolution)
Volume Scale: 10mm/L fixed for constant graphic comparison (as per ATS requirements)
Flow Scale: 5mm/L/sec fixed for constant graphic comparison (as per ATS requirements)
Flow Range: 16L/sec (although the ATS recommends only 14L/sec)
Volume Range: 20 litres
Accuracy: Exceeds ATS 1994 & 2005 recommendations.
BTPS Correction: Exp and INS
Standard(s) Compliance: ATS 1994, ATS Interpretive Strategies 1993, ECCS, ATS/ERS 2005, OSHA, NLHEP, ACOEM, EN 601, IEC 60601-1, ISO 13485:2003 & FDA 510K.
Power source: USB port powered.